Miro industries is excited to announce the official arrival of the latest addition to the miro product lineup the model 3 0.
Smacna duct support on roof.
This support can meet nearly all height requirements above the roof surface and is approved for seismic and high wind applications.
Page 2 106 the load is 146 lbs load for 70 inches x.
Seismic supports are not required for hvac ductwork when the i p 1 0 if either of the following conditions is met for the entire duct run.
Information required for duct construction 1.
Duct construction ductwork and supports shall conform to the hvac duct construction standards metal and flexible third edition 2005.
Tip you can figure the load on a duct of half of the width using table 2 46 and then double the load.
Duct dimensions duct dimensions shown in the contract.
Featuring a similar design to the time tested model 1 5 the model 3 0 is just as simple to install and is guaranteed to withstand harsh rooftop conditions for years to come.
Duct over 120 inches determine the tie rod load.
Roof hvac duct supports unistrut roof support system bases roof crossover stairs crossover ramps s 5.
Ducts are suspended from hangers 12 in.
2 500 pa w g.
For all ducts between the supply fan and variable volume control boxes and 1 250 pa w g.
140 2 70 inches rs 28 inches duct over 120 inches.
A copper roof was used on the rebuilt old senate chamber in 1819.
For all other ducts of any application.
Sheet metal and air conditioning contractors national association 4201 lafayette center drive chantilly virginia 20151 1219 tel 703 803 2980 fax 703 803 3732.
Duct over 120 inches.
Substrate failed early metal roofs were batten style or flat seamed until.
A comprehensive duct layout indicating sizes design airflows pressure class and routing of the duct system.
Snow retention systems zsi safety products s 5.
Solar attachment clamps for metal roofs unistrut tools hardware s 5.
Or less as measured from the top of the duct to the bottom of the support where.
The php d duct support leverages a goal post design with a single crossbar below the duct to support all sizes of square or round ducting cable trays and piping.
Replaced in a 1900 renovation the slate roof on the white house was replaced with sheet iron in 1804 the copper roof on the old church of christ in philly lasted from the 1830s to 1967.
The types of fittings to be used based on the designer s calculations of fitting losses i e square versus 45 entry taps conical versus straight taps etc.